2206 SLIT LAMP  |
|
|
Eye Pieces |
:
10x, 15x |
|
Objective |
: 1x,
1.6x |
|
Total Magnification |
: 10x, 16x and 24x |
|
ILLUMINATION |
|
|
Slit Image Rotation |
: 0
to 180 |
|
Tilting Angle |
: upto 20 |
|
Filter Disc |
: Cobalt
Blue, Green Filter, Yellow Filter,
Two open apertures |
|
Slit Diaphragm Disc |
: Six
apertures of 12,9,6,3,1 and 0.2mm and a wedge shaped
diaphragm for infinitely variable slit lengths |
|
Halogen Lamp |
: 12V - 50W |
|
STANDARD ACCESSORIES |
|
|
15X Eyepieces |
Testing Rod |
|
Replacing Mirror |
Spare Fuse |
|
Hruby Lens |
Dust Cover |
|
Plastic breath shield |
Replacing Lamp one piece for illumination
unit |
|
 |
|
|
|
| |
2206 ZOOM MAGNIFICATION  |
|
|
Microscope |
:
Galilean type |
|
Magnification Change |
:
Continuous Zoom |
|
Total
Magnification |
: 10x
to 50x |
|
ILLUMINATION |
|
|
Slit
Image Rotation |
: 0
to 180 |
|
Tilting Illumination |
: 5 to
20 |
|
Filter
Disc |
: Cobalt Blue, Red Free,
Natural Density, & Open Aperture |
|
Slit
Diaphragm Disc |
: Six
apertures of 12,9,6,3,1 and 0.2mm and a wedge shaped
diaphragm for infinitely variable slit lengths |
|
Halogen Lamp |
: 12V
- 50W |
|
STANDARD ACCESSORIES |
|
|
15X
Eyepieces |
Plastic breath shield |
|
Spare
Bulb 12V-50W |
Testing Rod |
|
Spare Reflecting Mirror |
Spare
Fuse |
|
Hruby Lens |
Dust Cover |
|
 |
|
|
|
| |
2206 STEPPER MAGNIFICATION  |
|
|
BINOCULAR MICROSCOPE |
|
Microscope |
:
Galilean type |
|
Magnification Change |
:
Continuous Zoom |
|
Total
Magnification |
: 10x
to 50x |
|
ILLUMINATION |
|
|
Slit
Image Rotation |
: 0
to 180 |
|
Tilting Illumination |
: 5 to
20 |
|
Filter
Disc |
: Cobalt Blue, Red Free,
Natural Density, & Open Aperture |
|
Slit
Diaphragm Disc |
: Six
apertures of 12,9,6,3,1 and 0.2mm and a wedge shaped
diaphragm for infinitely variable slit lengths |
|
Halogen Lamp |
: 12V
- 50W |
|
STANDARD ACCESSORIES |
|
|
15X
Eyepieces |
Plastic breath shield |
|
Spare
Bulb 12V-50W |
Testing Rod |
|
Spare Reflecting Mirror |
Spare
Fuse |
|
Hruby Lens |
Dust Cover |
|
 |
|
|
|
| |
2206 SURGICAL MICROSCOPES  |
|
|
MICROSCOPE SECTION |
|
Optical Head |
Indigenous |
|
Eye Piece |
Wide field 10x individually
adjustable |
|
Eye Inclination |
45 (ophthalmic) 90 (ENT & General) |
|
Interpupillary Distance |
Adjustable from 54mm to 75mm |
|
Working Distance |
200mm (300mm,400mm optional) |
|
Total Magnification |
5x to 25x variable |
|
Field of vision |
12 mm to 52.5 mm |
|
ILLUMINATION SECTION |
|
|
Type |
INAMI
type twin bulb system available with fibre cable
cold light guide 15V 150 Watts/24V 250 W |
|
Field of illumination |
55 mm |
|
STAND SECTION |
|
|
Type |
Floor
stand, Movable with castor
wheels |
Vertical movement of
counter balance arm |
300mm |
|
Fine Focussing |
Manual
40mm movement,Motorised with foot pedal |
|
Radius of rotation arm |
360 |
|
Base size |
570mm-590mm |
|
Weight |
45 Kg. approx |
|
 |
|
|
|
| |
2206 BINOCULAR SURGICAL LOUPE  |
|
|
Specially designed
operating loupe with magnification of 3.5x,
indigenous, fitted on extra fine light weight metal
frames/ plastic frames, having interpupillary
adjustment in both the tubes. |
|
Magnification |
3.5x |
|
Visual Field Diameter |
30mm |
|
Working Distance |
300mm |
|
Weight |
93grams |
| |
|
| |
|
|
 |
|
|
|
| |
2206 POWER TABLE  |
|
|
Height Minimum |
675 mm |
|
Height Maximum |
875 mm |
|
Vertical Travelling Range |
200 mm |
|
Load Maximum |
500 Kgs |
|
Table Top Size |
570x400x24 mm |
|
Power Supply AC |
240 V |
|
Weight |
26 Kg |
|
Up & Down Movement |
Tip & Foot Switch |
|
 |
|
|
|
| |
2206 LENSMETER  |
|
|
Model : MMTM - 96 |
|
Type |
Occular type external reading system |
|
Vertex Power Range
|
25D
Step : 0.25D step upto 10D
0.50D step beyond 10D |
|
Cylindrical Axis Scale |
0 to
180 (1 step) |
|
Target |
Cross & Corona |
|
Diameter of Lens Accomodated |
30 to
80 mm |
|
Tilting Angle |
30 to 90 |
|
Light Source |
AC 220V 3W LED |
| |
|
|
 |
|
|
|
| |
2206 KERATOMETER  |
|
-
Coincidence Focusing
System
-
One Position
instruments. Measure both meridians without changing
optical system.
-
Simple vertical
adjustable head to fit patient.
-
Astigmatic axis 0° to
180°.
-
The achromatic optical
systems to precise measurement of the corneal radius
curvature and accurate measurement of radius curvature
of contact lens.
-
Dual eye level sighting
system
-
Measuring range : Radius
of curvature, 9.4 - 6.4mm (in 0.05 steps)
-
Diopter 36 - 52 (in 0.25
steps)
-
Paint Finish :
Black or White.
|
|
 |
|
|
|
| |
|
|